31P saturation transfer and phosphocreatine imaging in the monkey brain.
AUTOR(ES)
Mora, B
RESUMO
31P magnetic resonance imaging with chemical-shift discrimination by selective excitation has been employed to determine the phosphocreatine (PCr) distribution in the brains of three juvenile macaque monkeys. PCr images were also obtained while saturating the resonance of the gamma-phosphate of ATP, which allowed the investigation of the chemical exchange between PCr and the gamma-phosphate of ATP catalyzed by creatine kinase. Superposition of the PCr images over the proton image of the same monkey brain revealed topological variations in the distribution of PCr and creatine kinase activity. PCr images were also obtained with and without visual stimulation. In two out of four experiments, an apparently localized decrease in PCr concentration was noted in visual cortex upon visual stimulation. This result is interpreted in terms of a possible role for the local ADP concentration in stimulating the accompanying metabolic response.
ACESSO AO ARTIGO
http://www.pubmedcentral.nih.gov/articlerender.fcgi?artid=52510Documentos Relacionados
- Free magnesium levels in normal human brain and brain tumors: 31P chemical-shift imaging measurements at 1.5 T.
- 31P nuclear magnetic relaxation studies of phosphocreatine in intact muscle: determination of intracellular free magnesium.
- Mitochondrial regulation of phosphocreatine/inorganic phosphate ratios in exercising human muscle: a gated 31P NMR study.
- Imaging the adult brain.