An Internal Control for Routine Diagnostic PCR: Design, Properties, and Effect on Clinical Performance
AUTOR(ES)
Rosenstraus, Maurice
FONTE
American Society for Microbiology
RESUMO
We constructed internal controls (ICs) to provide assurance that clinical specimens are successfully amplified and detected. The IC nucleic acids contain primer binding regions identical to those of the target sequence and contain a unique probe binding region that differentiates the IC from amplified target nucleic acid. Because only 20 copies of the IC are introduced into each test sample, a positive IC signal indicates that amplification was sufficient to generate a positive signal from targets present at the limit of test sensitivity. The COBAS AMPLICOR Chlamydia trachomatis, Neisseria gonorrhoeae, Mycobacterium tuberculosis, and human hepatitis C virus tests exhibited inhibition rates ranging from 5 to 9%. Approximately 64% of these inhibitory specimens were not inhibitory when a second aliquot was tested. Because repeatedly inhibitory specimens were not reported as false negative and because additional infected specimens were detected during retesting, test sensitivities were 1 to 6% greater than they would have been if the IC had not been used.
ACESSO AO ARTIGO
http://www.pubmedcentral.nih.gov/articlerender.fcgi?artid=124832Documentos Relacionados
- Stable and Noncompetitive RNA Internal Control for Routine Clinical Diagnostic Reverse Transcription-PCR
- Making Internal Amplification Control Mandatory for Diagnostic PCR
- Quantitative PCR: validation of the use of a multispecific internal control.
- Practical Considerations in Design of Internal Amplification Controls for Diagnostic PCR Assays
- Multiplex PCR: Optimization and Application in Diagnostic Virology