Comparison of Five Methods for Extraction of Legionella pneumophila from Respiratory Specimens
AUTOR(ES)
Wilson, Deborah
FONTE
American Society for Microbiology
RESUMO
The efficiencies of five commercially available nucleic acid extraction methods were evaluated for the recovery of a standardized inoculum of Legionella pneumophila in respiratory specimens (sputum and bronchoalveolar lavage [BAL] specimens). The concentrations of Legionella DNA recovered from sputa with the automated MagNA Pure (526,200 CFU/ml) and NucliSens (171,800 CFU/ml) extractors were greater than those recovered with the manual methods (i.e., Roche High Pure kit [133,900 CFU/ml], QIAamp DNA Mini kit [46,380 CFU/ml], and ViralXpress kit [13,635 CFU/ml]). The rank order was the same for extracts from BAL specimens, except that for this specimen type the QIAamp DNA Mini kit recovered more than the Roche High Pure kit.
ACESSO AO ARTIGO
http://www.pubmedcentral.nih.gov/articlerender.fcgi?artid=535306Documentos Relacionados
- Direct immunofluorescent detection of Legionella pneumophila in respiratory specimens.
- Enhancement of recovery of Legionella pneumophila from contaminated respiratory tract specimens by heat.
- Comparison of blood culture methods for recovery of Legionella pneumophila from the blood of guinea pigs with experimental infection.
- Isolation of Legionella pneumophila from hospital potable water specimens: comparison of direct plating with guinea pig inoculation.