Confirmation of Legionella pneumophila cultures with a fluorescein-labeled monoclonal antibody.
AUTOR(ES)
Tenover, F C
RESUMO
We compared a fluorescein-labeled monoclonal antibody directed against an outer membrane protein of Legionella pneumophila (Genetic Systems Corp. [GSC], Seattle, Wash.) with a similarly labeled polyclonal reagent (L. pneumophila serogroups 1 to 6, poly; BioDx, Inc., Denville, N.J.) for the confirmation of L. pneumophila isolates grown in culture. Duplicate suspensions of 52 organisms, including 21 L. pneumophila and 8 non-L. pneumophila species of legionella, were placed on individual glass slides, fixed, and stained with both reagents, and the results were compared. Both antisera correctly identified all L. pneumophila serogroups 1 to 6, but only the GSC reagent produced definitive staining of the L. pneumophila isolates of serogroups 7, 8, and 9. Additionally, the GSC reagent produced more uniform staining patterns around the legionella bacilli and displayed little background fluorescence when compared with the BioDx reagent.
ACESSO AO ARTIGO
http://www.pubmedcentral.nih.gov/articlerender.fcgi?artid=271831Documentos Relacionados
- Comparison of cross-staining reactions by Pseudomonas spp. and fluorescein-labeled polyclonal and monoclonal antibodies directed against Legionella pneumophila.
- Hen Fluorescein-Labeled Gonococcal Lipopolysaccharide Antibody in the Delayed Fluorescent Antibody Technique for the Confirmation of Neisseria gonorrhoeae
- Viral Identification by Scanning Electron Microscopy of Preparations Stained with Fluorescein-Labeled Antibody
- Fluorescein-labeled β-Glucosidase as a Bacterial Stain
- Cooperative binding of fluorescein-labeled clupeine by DNA.