Detection of antibodies to tetanus toxoid: comparison of a direct haemagglutination method with a radioimmunoassay.
AUTOR(ES)
Wang, A S
RESUMO
Two methods of detecting antibodies to tetanus toxoid were compared, a radioimmunoassay (RIA) employing radiolabelled staphylococcal protein A and a direct haemagglutination (HA) method employing sheep erythrocytes coupled to tetanus toxoid with chromic chloride. These were shown to have a similarly high specificity with the HA method showing slightly higher sensitivity. Haemagglutination offers several additional advantages in terms of simplicity, low cost and less requirement for specialised equipment. The assays were also used to demonstrate a transient IgM response after repeated booster injections with absorbed toxin given to seropositive individuals, and these antibodies were found to be protective in biological tests.
ACESSO AO ARTIGO
http://www.pubmedcentral.nih.gov/articlerender.fcgi?artid=497898Documentos Relacionados
- Studies on Tetanus Toxoid: III. Antitoxic Response in Guinea Pigs Immunized with Tetanus Alum-precipitated Toxoid Followed by Tetanus Spores
- Enzyme-linked immunosorbent assay for detection of capsular antibodies against Haemophilus influenzae type b: comparison with radioimmunoassay.
- Enzyme-linked immunosorbent assay for measurement of antibodies against pneumococcal polysaccharide antigens: comparison with radioimmunoassay.
- Comparison of Enzyme-Linked Immunosorbent Assay and Passive Hemagglutination Method for Quantification of Antibodies to Lipopolysaccharide and Tetanus Toxoid in Rats