Enzyme immunoassay using a novel recombinant polypeptide to detect human immunodeficiency virus env antibody.

AUTOR(ES)
RESUMO

A unique antigen, CBre3, has been synthesized from a genetically engineered clone to detect human immunodeficiency virus (HIV) env antibodies with high sensitivity and specificity. The antigen contains sequences derived from both envelope proteins of HIV, i.e., gp120 and gp41, and was purified free of Escherichia coli proteins detectable by Coomassie stain or immunoblotting with E. coli antiserum. The purified recombinant polypeptides were used as antigen in an enzyme immunoassay (EIA) to screen serum samples from healthy and HIV-infected individuals. The same samples were also tested by radioimmunoprecipitation (RIP) for gp120 and gp160 HIV antibodies. All samples containing gp120 and gp160 antibodies by RIP had CBre3 EIA values greater than 0.35 (n, 122; range, 0.37 to 2.1+; median, 1.65). All RIP HIV antibody-negative samples had CBre3 EIA values less than 0.25 (n, 140; mean, 0.052; standard deviation, 0.045; range, 0.00 to 0.22). The endpoint titer of a standard positive control serum was 1:10,000 by RIP and by CBre3 EIA. The assay was 100% accurate in three proficiency panels. It easily detected six samples from individuals whose infections were confirmed by culture; these samples were reactive only with p24 by Western blot. The samples also were positive for gp120 and gp160 antibodies by RIP. These data suggest that the CBre3 EIA can detect env antibodies as sensitively and specifically as RIP and with more sensitivity than Western blot.