Improved Version 2.0 Qualitative and Quantitative AMPLICOR Reverse Transcription-PCR Tests for Hepatitis C Virus RNA: Calibration to International Units, Enhanced Genotype Reactivity, and Performance Characteristics
AUTOR(ES)
Lee, Sung C.
FONTE
American Society for Microbiology
RESUMO
Version 2.0 qualitative and quantitative AMPLICOR reverse transcription-PCR tests for HCV were designed to improve on the performance of first version of the hepatitis C virus (HCV) tests. The new tests were calibrated in international units, the new commonly accepted standard unit of measurement for HCV RNA. The sensitivity of the qualitative tests was enhanced by modifying the specimen processing procedure to achieve a limit of detection 50 IU/ml. The limit of detection for the quantitative tests was 600 IU/ml. Modifications to the amplification reaction mixture and thermal cycling conditions enabled all genotypes to be amplified with similar efficiency. The quantitative tests exhibited a linear range extending from 500 to 500,000 IU/ml and excellent reproducibility, with coefficients of variation ranging from 18 to 39%, within the linear range. These data indicate that the version 2.0 AMPLICOR HCV tests will improve diagnosis of HCV infection and will yield more-accurate titers for prognosis and for monitoring therapeutic efficacy, particularly at low viral loads. Furthermore, it will be possible to compare the performance characteristics and viral load measurements of AMPLICOR tests to those of other tests that adopt the international unit as the standard of measurement.
ACESSO AO ARTIGO
http://www.pubmedcentral.nih.gov/articlerender.fcgi?artid=87559Documentos Relacionados
- Performance of the COBAS AMPLICOR HCV MONITOR Test, Version 2.0, an Automated Reverse Transcription-PCR Quantitative System for Hepatitis C Virus Load Determination
- Qualitative Detection of Hepatitis C Virus RNA: Comparison of Analytical Sensitivity, Clinical Performance, and Workflow of the Cobas Amplicor HCV Test Version 2.0 and the HCV RNA Transcription-Mediated Amplification Qualitative Assay
- Reverse transcription-PCR detection of hepatitis G virus.
- Clinical Evaluation of the Automated COBAS AMPLICOR HCV MONITOR Test Version 2.0 for Quantifying Serum Hepatitis C Virus RNA and Comparison to the Quantiplex HCV Version 2.0 Test
- Performance Characteristics of the COBAS Amplicor Hepatitis C Virus (HCV) Monitor, Version 2.0, International Unit Assay and the National Genetics Institute HCV Superquant Assay