Value and Interpretation of Serological Tests for the Diagnosis of Cryptococcosis
AUTOR(ES)
Kaufman, Leo
RESUMO
Maximal serological diagnosis of cryptococcosis may be accomplished through the concurrent use of three tests: the latex agglutination (LA) test for cryptococcal antigen, and the indirect fluorescent antibody (IFA) and tube agglutination (TA) tests for Cryptococcus neoformans antibodies. These tests were applied to 141 serum and cerebral spinal fluid specimens from 66 culturally proven cases of cryptococcosis and to 42 sera from normal subjects and from patients with other systemic mycotic diseases. The LA test was sensitive and completely specific; of the sera from proven cases, 55% were positive. With the TA test, 37% of the specimens were positive and the test was highly specific. With the IFA test, 38% of the specimens were positive and the test appears to be the least specific of the three. Cross-reactions were most evident with blastomycosis and histoplasmosis case sera. When the three tests were used concurrently, 87% of the cryptococcosis case specimens were positive and permitted a presumptive diagnosis of C. neoformans infections in 61 (92%) of the 66 patients whose specimens were examined.
ACESSO AO ARTIGO
http://www.pubmedcentral.nih.gov/articlerender.fcgi?artid=547794Documentos Relacionados
- Laboratory diagnosis and interpretation of tests for syphilis.
- Interpretation of positive serological tests for syphilis in pregnancy.
- The Value of Serological Tests for the Identification of Pseudomonas malvacearum
- A comparison of serological tests for the diagnosis of gonorrhoea.
- A Comparison of Seven Tests for Serological Diagnosis of Tuberculosis