Fia Amperometric Detection
Mostrando 1-12 de 17 artigos, teses e dissertações.
-
1. DETERMINAÇÃO RÁPIDA E SIMPLES DE CITRATO DE SILDENAFILA (VIAGRA® E GENÉRICOS) EMPREGANDO ELETRODO IMPRESSO DE CARBONO EM SISTEMAS FIA E BIA COM DETECÇÃO AMPEROMÉTRICA
This work presents two amperometric methods for Sildenafil Citrate (SC) determination in erectile dysfunction drugs (Viagra® and Generics), using Batch Injection Analysis (BIA) and Flow Injection Analysis (FIA) systems with a cell for Screen Printed Electrodes (SPE). In Britton- Robinson buffer solution (pH 2), the SC presented an irreversible anodic peak a
Quím. Nova. Publicado em: 2017-08
-
2. Desenvolvimento de um sistema de análise por injeção em fluxo utilizando materiais alternativos de baixo custo para fins didáticos
This work describes a simple and inexpensive flow injection analysis system in which gravity force provides fluid propulsion while needles for insulin administration or metallic wires act as electrodes for amperometric detection. The proposed system was able to demonstrate the influence of several operational parameters on the transient signals. Moreover, th
Quím. Nova. Publicado em: 2014
-
3. Determinação de nimesulida por análise por injeção em fluxo com detecção amperométrica de múltiplos pulsos
A simple and fast method for the determination of nimesulide (NI) using flow injection analysis with multiple-pulse amperometric (FIA-MPA) detection at a boron-doped diamond (BDD) electrode was developed. The method was based mainly on the application of a four-potential waveform, E1(det) = -0.8 V / 30 ms, E2(det) = 0.6 V / 30 ms, E3(det) = -0.4 V / 30 ms an
Quím. Nova. Publicado em: 2013
-
4. Determinação eletroquímica de glicerol em biodiesel por amperometria de múltiplos pulsos com eletrodo de ouro
Biodiesel is the fuel obtained from vegetable oils or animal fats that can partially or totally replace diesel oil. Besides being obtained from renewable sources, biodiesel is less polluting than diesel and biodegradable. One disadvantage of biodiesel is the byproduct of transesterification reaction of raw material, glycerol, which can cause damages to combu
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 22/06/2012
-
5. Determination of sildenafil citrate (Viagra®) in various pharmaceutical formulations by flow injection analysis with multiple pulse amperometric detection
O presente trabalho apresenta uma metodologia simples, rápida e de baixo custo para a determinação de citrato de sildenafila (SC) em formulações farmacêuticas de referência (Viagra®) e em produtos similares, genéricos e manipulados, por amperometria de múltiplos pulsos em sistema FIA (análise por injeção em fluxo). O método consiste na aplicaç
J. Braz. Chem. Soc.. Publicado em: 09/10/2012
-
6. Fabricação, caracterização do comportamento eletroquímico e aproveitamento analítico de eletrodos modificados para a determinação de peróxido de hidrogênio / Fabrication, characterization of the electrochemical behavior and analytical use of modified electrodes for the determination of hydrogen peroxide
Neste trabalho são apresentados resultados sobre o desenvolvimento de um sensor visando à utilização no monitoramento de peróxido de hidrogênio em amostras de reações Fenton. Superfícies eletródicas modificadas com filmes de poli-azul de metileno (PMB) e óxido de rutênio de hexacianoferrato (RuOHCF) sem e com a incorporação de nanotubos de carb
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 04/11/2011
-
7. Desenvolvimento de procedimentos eletroanalíticos para a determinação de antioxidantes e corantes em produtos alimentícios empregando um eletrodo de diamante dopado com boro / Development of electroanalytical procedures for the determination of antioxidants and colorants in food samples using a boron-doped diamond electrode
The following topics were investigated in this thesis: a) the electrochemical response of a boron-doped diamond electrode, after different electrochemical pretreatments, for two antioxidants (butylated hydroxyanisole BHA and butylated hydroxytoluene BHT) and three food colorants (tartrazine TT, sunset yellow SY, and brilliant blue BB); b) the development of
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 29/04/2011
-
8. Análise por injeção em fluxo com detecção amperométrica de múltiplos pulsos: potencialidades e aplicações
The potentialities and applications of the Multiple Pulse Amperometric detection (MPA) coupled with Flow Injection Analysis (FIA) are evaluated. Important aspects as cleaning and activation of electrode surface, indirect and simultaneous analysis of electroactive compounds and the use of the internal standard method for quantifications utilizing FIA-MPA are
Química Nova. Publicado em: 2011
-
9. Determinação de peróxido de hidrogênio em antisséptico bucal usando um microdispositivo contendo partículas de Azul da Prússia
A simple flow-injection amperometric procedure using a three-electrode-integrated sensor for the determination of H2O2 in antiseptic mouthwash is reported. This method involves the use of a working composite electrode modified with Prussian Blue (PB) particles that was easily adapted as detector in FIA. The best amperometric response was observed for a compo
Química Nova. Publicado em: 2011
-
10. Electrosynthesis and characterizations of polypyrrole-2-carboxylic acid for application as amperometric biosensor constructed in microelectrodes / Eletrossíntese e caracterização de filmes de polipirrol-2-ácido carboxílico para uso em biossensores amperométricos construídos em eletrodos miniaturizados
In this work, we present the electrochemical synthesis of a new conducting polymer derived of polypyrrole (PPI) functionalized by carboxylic group, the polypyrrole-2-carboxylic acid, and its application as amperometric transducer in biosensor by use of polyphenol oxidase (PFO). All the steps of syntheses and characterization of the polymer film in microelect
Publicado em: 2009
-
11. Novos materiais para aplicações analíticas nas determinações de compostos orgânicos de interesse farmacêutico e ambiental / New materials for analytical application in organic compound determination for pharmaceutical and environmental interests
Carbon film sensors, built from resistors of 2 Ω nominal resistance, were employed for application in the environment and pharmaceutical fields without previous modification of the electrode surface. When these sensors are electrochemically treated they obtain a wider potential window (both anodic and cathodic regions) than many other forms of carbon. D
Publicado em: 2009
-
12. Studies for the amperometric determination of total nitrophosphates in waters in flow injection analysis / Estudos para a determinação amperométrica de nitrofosforados totais em águas em sistema de análise por injeção em fluxo
An electrochemical determination methodology of Parathion was investigated based on the amperometric detection of multiple pulses in a flow injection analysis system (FIA). A propulsion system without pulsation and an electrochemical detector for flow analysis systems were built and investigated for this determination. Studies of the electrochemical behavior
Publicado em: 2007