Ionization Chamber
Mostrando 1-12 de 26 artigos, teses e dissertações.
-
1. Simultaneous determination of candesartan and hydrochlorothiazide in human plasma by LC-MS/MS
Abstract A simple, sensitive, rapid and highly efficient LC-MS/MS method was developed for the determination of Candesartan and Hydrochlorothiazide simultaneously in human plasma. The method employed Zorbax eclipse C18 (150 X 4.6 mm, 5µ) column using acetate buffer: acetonitrile (25:75%, v/v) as the mobile phase. The mobile phase flow rate is 1 mL/min which
Braz. J. Pharm. Sci.. Publicado em: 07/06/2018
-
2. Development and evaluation of an inhalation chamber for in vivo tests
ABSTRACT The bioavailability, toxicity, and therapeutic efficacy of a drug is directly related to its administration route. The pulmonary route can be accessed by inhalation after fumigation, vaporization or nebulization. Thus, pharmacological and toxicological evaluation accessed by an apparatus specifically designed and validated for this type of administr
An. Acad. Bras. Ciênc.. Publicado em: 17/08/2017
-
3. CARACTERIZAÇÃO DE DISPOSITIVOS ELETRÔNICOS PARA DOSIMETRIA EM TOMOGRAFIA COMPUTADORIZADA. / CHARACTERIZATION OF ELECTRONIC DEVICES FOR DOSIMETRY IN COMPUTED TOMOGRAPHY.
Computed tomography (CT) is an examination of high diagnostic capability that delivers high doses of radiation compared with other diagnostic radiological examinations. The current CT dosimetry is mainly made by using a 100 mm long ionization chamber. However, it was verified that this extension, which is intended to collect all scattered radiation of the si
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 12/03/2012
-
4. Caracterização e aplicação de duas câmaras de extrapolação em feixes padronizados de radiação X / Characterization and application of two extrapolation chambers in standard X radiation beams
The extrapolation chambers are ionization chambers with variable volume, and they are mainly utilized as beta radiation detectors. In this work two extrapolation chambers were characterized, a commercial PTW extrapolation chamber and another extrapolation chamber developed at the Calibration Laboratory of IPEN, for application as reference systems in mammogr
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 31/03/2011
-
5. Metodologia de controle de qualidade e implantação de campos padrões de radiação X, nível mamografia, seguindo a norma IEC 61267 / Quality control methodology and implementation of X-radiation standards beams, mammography level, following the standard IEC 61267
In this work it was developed and applied a quality control program of the Xradiation system (160 kV, constant potential, target of tungsten) of the Calibration Laboratory of IPEN(LCI) in the energy range relative to mammography beams (from 25 kV to 35 kV). The X radiation standards beams, level mammography, using molybdenum and aluminum as additional filtra
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 24/11/2010
-
6. Estabelecimento de um novo método de calibração de câmaras de ionização tipo lápis para dosimetria em feixes de tomografia computadorizada / Establishment of a new calibration method of pencil ionization chamber for dosimetry in computed tomography
Pencil ionization chambers are used for beam dosimetry in computed tomography equipment (CT). In this study, a new calibration methodology was established, in order to make the Calibration Laboratory of Instituto de Pesquisas Energéticas e Nucleares (LCI) suitable to international metrological standards, dealing with specific procedures for calibration of t
Publicado em: 2010
-
7. Determination of dosimetric quantities of interest in Mammography using thermoluminescent detectors. / Determinação de grandezas dosimétricas de interesse em mamografia usando detectores termoluminescentes
National and international health organizations such as the Brazilian Ministry of Health, through its Secretary of Health Surveillance establishes in the publication Nº 453/98 that in all mammographic equipments must be evaluated the entrance-skin dose through the readings of an ionization chamber-electrometer system corrected by the backscatter factor, amo
Publicado em: 2010
-
8. Dose rate influence on deep dose deposition using a 6 MV x-ray beam from a linear accelerator
Linear accelerators used in radiation therapy treatments usually provide the capability of irradiating with different dose rates. The medical physicist may choose arbitrary the dose rate to use, although the relative biological effectiveness (RBE) varies with this physical parameter. In this work the measurements of absorbed dose of the x-ray beams from a Va
Brazilian Journal of Physics. Publicado em: 2009-06
-
9. A comparison between channel selections in heavy ion reactions
The gamma rays de-exciting the yrast and near yrast states in neutron deficient as well as neutron rich nuclei from fusion-evaporation and deep-inelastic reactions and other emission particles have been recorded using an array of escape suppressed germanium detectors, a BGO ball, a recoil separator, silicon charge particle detectors and an ionization chamber
Brazilian Journal of Physics. Publicado em: 2009-03
-
10. Development of a calibration methodology for instruments used to interventional radiology quality control / Desenvolvimento de uma metodologia para a calibração de instrumentos de medida utilizados no controle da qualidade em radiodiagnóstico intervencional
Interventional radiology is the technique where X radiation images are used as a tool in the conduction of diagnostic or/and therapeutic procedures. The exposition times are long for both procedures, diagnostic and therapeutic, may cause serious injuries in the patient, and also contribute to the dose of the clinical staff. In Brazil there are not yet well e
Publicado em: 2009
-
11. AvaliaÃÃo dos parÃmetros dosimÃtricos em feixes de FÃtons de Radioterapia usando fototransistor SMT
One of the biggest challenges in radiotherapy dosimetry is to certify that the prescribed dose is given to the patient. For this, it is necessary to use small detectors to evaluate the beam parameters. Current dosimetry is realized with detectors that highlight problems: high cost, difficulty in handling, absence of real time readout, complex and delayed obt
Publicado em: 2008
-
12. Dosimetric Parameters and Diffusion Coefficient through Fricke Xylenol Gel dosimeter, for Small Field Sizes Electron Beams / Parâmetros dosimétricos e coeficiente de difusão para elétrons em campos pequenos, através do dosímetro Fricke Xilenol Gel
Dosimetric parameters such as Percentage Depth Dose, Field Profile and Output Factor are necessary in radiotherapy routine, once they can help to improve the quality of the treatment and consequently of the absorbed dose delivered to the tumor. In this work the dosimetric parameters for electron beams of 8 and 10 MeV were measured with the chemical dosimeter
Publicado em: 2007